Amd-raidxpert2 User Guide


  Create a RAIDABLE Array



Baixar 1.1 Mb.
Pdf preview
Página85/216
Encontro10.02.2022
Tamanho1.1 Mb.
#21544
1   ...   81   82   83   84   85   86   87   88   ...   216
RAIDXpert2.UserGuide.enu
6.4.2.2 
Create a RAIDABLE Array 
Note: Refer to Table 7 for RAIDABLE array characteristics. 
1.  At the RAIDXpert2 Configuration Utility’s Main Menu, use the arrow keys to select 
Array Management, then press Enter 
2.  Use the arrow keys to select Create Array, then press Enter
3.  Use the arrow keys to select Select RAID Level, then press Enter
•  From the Select RAID Level Drop down menu, use the arrow keys to select 
RAIDABLE, then press Enter
4.  Select the disk with which to create the array: 
•  Use the arrow keys to select Select Physical Disks, then press Enter. 
•  Select an individual disk, highlight a disk with the arrow keys and press the Space 
Bar or Enter.  
•  Use the arrow keys to select Apply Changes, then press Enter
5.  Please refer to Table 17 on page 55 for Default Cache Tag Size. 
6.  Using the arrow keys to select Read Cache Policy, then press Enter
•  Select the desired Read Cache Policy, then press Enter
7.  Using the arrow keys to select Write Cache Policy, then press Enter
•  Select the desired Write Cache Policy, then press Enter
8.  Use the arrow keys to select Create Array, then press Enter


 
 
AMD-RAIDXpert2 User Guide 
53987  Rev. 3.10  June 2019  
 
56 
RAIDXpert2 Configuration Utility (HII) 
 Chapter 6 
 
6.4.2.3 
Create a VOLUME Array 
Note: Refer to Table 7 for VOLUME array characteristics  
9.  At the RAIDXpert2 Configuration Utility’s Main Menu, use the arrow keys to select 
Array Management, then press Enter.  
10. Use the arrow keys to select Create Array, then press Enter.  
11. Use the arrow keys to select Select RAID Level, then press Enter.  
•  From the Select RAID Level Drop down menu, use the arrow keys to select 
VOLUME, then press Enter.  
12. Select the disks with which to create the array:  
•  Use the arrow keys to Select Physical Disks, then press Enter.  
•  Select desired disks, highlight a disk with the arrow keys and press the Space Bar 
or Enter.  
•  Use the arrow keys to select Apply Changes, then press Enter.  
13. Please refer to Table 17 on page 55 for Default Cache Tag Size. 
14. Using the arrow keys to select Read Cache Policy, then press Enter.  
•  Select the desired Read Cache Policy, then press Enter.  
15. Using the arrow keys to select Write Cache Policy, then press Enter.  
•  Select the desired Write Cache Policy, then press Enter.  
16. Use the arrow keys to select Create Array, then press Enter.  
6.4.2.4 
Create a RAID0 Array  
Note: Refer to Table 7 for RAID0 array characteristics  
1.  At the RAIDXpert2 Configuration Utility’s Main Menu, use the arrow keys to select 
Array Management, then press Enter.  
2.  Use the arrow keys to select Create Array, then press Enter.  
3.  Use the arrow keys to select Select RAID Level, then press Enter.  
•  From the Select RAID Level Drop down menu, use the arrow keys to select 
RAID0, then press Enter.  
4.  Select the disks with which to create the array:  
•  Use the arrow keys to Select Physical Disks, then press Enter.  
•  Select desired disks, highlight a disk with the arrow keys and press the Space Bar 
or Enter.  
•  Use the arrow keys to select Apply Changes, then press Enter.  
5.  Please refer to Table 17 on page 55 for Default Cache Tag Size. 
6.  Using the arrow keys to select Read Cache Policy, then press Enter.  
•  Select the desired Read Cache Policy, then press Enter.  
7.  Using the arrow keys to select Write Cache Policy, then press Enter.  


 
 
53987  Rev. 3.10  June 2019 
 
  AMD-RAIDXpert2 User Guide 
 
 Chapter 6 
RAIDXpert2 Configuration Utility (HII) 
57 
 
•  Select the desired Write Cache Policy, then press Enter.  
8.  Use the arrow keys to select Create Array, then press Enter.  
6.4.2.5 
Create a RAID1 Array  
Note: Refer to Table 7 for RAID1 array characteristics  
1.  At the RAIDXpert2 Configuration Utility’s Main Menu, use the arrow keys to select 
Array Management, then press Enter.  
2.  Use the arrow keys to select Create Array, then press Enter.  
3.  Use the arrow keys to select Select RAID Level, then press Enter.  
•  From the Select RAID Level Drop down menu, use the arrow keys to select 
RAID1, then press Enter.  
4.  Select the disks with which to create the array:  
•  Use the arrow keys to Select Physical Disks, then press Enter.  
•  Select desired disks, highlight a disk with the arrow keys and press the Space Bar 
or Enter.  
•  Use the arrow keys to select Apply Changes, then press Enter.  
5.  Please refer to Table 17 on page 55 for Default Cache Tag Size. 
6.  Using the arrow keys to select Read Cache Policy, then press Enter.  
•  Select the desired Read Cache Policy, then press Enter.  
7.  Using the arrow keys to select Write Cache Policy, then press Enter.  
•  Select the desired Write Cache Policy, then press Enter.  
8.  Use the arrow keys to select Create Array, then press Enter.  
6.4.2.6 
Create a RAID10 Array  
Note: Refer to Table 7 for RAID10 array characteristics  
1.  At the RAIDXpert2 Configuration Utility’s Main Menu, use the arrow keys to select 
Array Management, then press Enter.  
2.  Use the arrow keys to select Create Array, then press Enter.  
3.  Use the arrow keys to select Select RAID Level, then press Enter.  
•  From the Select RAID Level Drop down menu, use the arrow keys to select 
RAID10, then press Enter.  
4.  Select the disks with which to create the array:  
•  Use the arrow keys to Select Physical Disks, then press Enter.  
•  Select desired disks, highlight a disk with the arrow keys and press the Space Bar 
or Enter.  
•  Use the arrow keys to select Apply Changes, then press Enter.  
5.  Please refer to Table 17 on page 55 for Default Cache Tag Size. 


 
 
AMD-RAIDXpert2 User Guide 
53987  Rev. 3.10  June 2019  
 
58 
RAIDXpert2 Configuration Utility (HII) 
 Chapter 6 
 
6.  Using the arrow keys to select Read Cache Policy, then press Enter.  
•  Select the desired Read Cache Policy, then press Enter.  
7.  Using the arrow keys to select Write Cache Policy, then press Enter.  
•  Select the desired Write Cache Policy, then press Enter.  
8.  Use the arrow keys to select Create Array, then press Enter
6.5 
Delete Arrays  
CAUTION: Deleting an array permanently destroys all data that is on the array. This action 
cannot be undone and it is very unlikely the data can be recovered. 
CAUTION: Do not delete the first array listed in the Arrays section, if it is the AMD-RAID 
bootable array. Doing this deletes the operating system and AMD-RAID files. 
6.5.1 
Delete an Array 
1. 
At the RAIDXpert2 Configuration Utility’s Main Menu, use the arrow keys to select 
Array Management, then press Enter
2. 
Use the arrow keys to select Delete Arrays then press Enter.  
3. 
Select the array(s) to delete: 
•  Use the arrow keys to select the desired array or multiple arrays, then press the Space 
Bar or Enter to change option to Enabled for deletion. 
•  If you want to select all of the arrays, use the arrow keys to select Check all, then press 
Enter. 
•  Use the arrow keys to select Delete Array, then press the Space Bar or Enter. 
•  To select all the arrays for deletion: use the arrow keys to select Check all, then press 
the Space Bar or Enter. 
•  Review the warning message, if you want to proceed, press the Space Bar or Enter. 
•  Use the arrow keys to select, Yes to Delete arrays or press the ESC key to exit. 
6.6 
Manage Spares 
This option allows the user to assign or unassign global or dedicated spares. 
Note: In order to assign a physical disk as a Global Spare, it must not be part of any Array. 
6.6.1 
Assign Global Spares 
1. 
At the RaidXpert2 Configuration Utility’s Main Menu, use the arrow keys to select 
Physical Disk Management, then press Enter
2. 
Use the arrow keys to select Select Physical Disk Operations, then press Enter
3. 
Use the arrow keys to select Select Physical Disk, then press Enter
4. 
Use the arrow keys to select Assign Global Hot Spare, then press Enter


 
 
53987  Rev. 3.10  June 2019 
 
  AMD-RAIDXpert2 User Guide 
 
 Chapter 6 
RAIDXpert2 Configuration Utility (HII) 
59 
 
5.  Review the warning message, if you want to proceed, use the arrow keys to select Yes or 
press ESC or select No, to exit. 
6.6.2 
Assign Dedicated Spares 
Note:  Dedicated spares can only be assigned to redundant arrays and must the same size or 
larger than the other members of the redundant array. 
1.  At the RAIDXpert2 Configuration Utility’s Main Menu, use the arrow keys to select 
Array Management, then press Enter.  
2.  Use the arrow keys to select Manage Array Properties, then press Enter
3.  Use the arrow keys to select Select Array
•  From the drop down menu, select the desired array (must be a redundant array), then 
press Enter
4.  Use the arrow keys to select Manage Dedicated Hot Spares, then press Enter
5.  Select the disks to assign as dedicated spares. 
•  To select the disk, use the arrow keys to highlight the disk and press the Space Bar 
or Enter to select it. 
•  Use the arrow keys to select Add Hot Spare Physical Disk, then press Enter. 
•  At the warning message, press the space bar or Enter to Confirm. 
•  Use the arrow keys to select Yes, then press Enter or press the ESC key to exit 
adding the Dedicated Spare. 

Baixar 1.1 Mb.

Compartilhe com seus amigos:
1   ...   81   82   83   84   85   86   87   88   ...   216




©historiapt.info 2022
enviar mensagem

    Página principal