Amd-raidxpert2 User Guide



Baixar 1.1 Mb.
Pdf preview
Página201/216
Encontro10.02.2022
Tamanho1.1 Mb.
#21544
1   ...   197   198   199   200   201   202   203   204   ...   216
RAIDXpert2.UserGuide.enu
 
 
53987  Rev. 3.10  June 2019 
 
  AMD-RAIDXpert2 User Guide 
 
 Chapter 11 
Troubleshooting 
137 
 
Table 40. An Array is in a Critical State 
Possible Causes 
Additional Information 
Corrective Actions 
One or more disks in the 
array have failed or been 
removed. 
Due to the failed disk or disks, the array is no 
longer maintaining redundant (mirrored or parity) 
data.  
The failure of an additional disk results in an 
Offline state and lost data.  
See Section 11.5.1, 
Troubleshooting Disks, 
on page 139. 
 
Table 41. An Array is in an Offline State 
Possible Causes 
Additional Information 
Corrective Actions 
The array has lost the 
maximum allowable disks 
per RAID level. 
One or more disks have failed. 
•  If the array is non-redundant, the failure of a 
single disk causes the array to fail. 
•  If the array is redundant, the failure of two or 
more disks causes the array to fail.  
The array cannot be restored (rebuilt). 
See Section 11.5.1, 
Troubleshooting Disks, 
on page 139. 
 

Baixar 1.1 Mb.

Compartilhe com seus amigos:
1   ...   197   198   199   200   201   202   203   204   ...   216




©historiapt.info 2022
enviar mensagem

    Página principal