53987 Rev. 3.10 June 2019
AMD-RAIDXpert2 User Guide
Chapter 11
Troubleshooting
135
Table 38. POST Screen Warning Messages (Continued)
Warning Message
Additional Information
Corrective Action
WARNING: Found
arrays that are Offline
[or equivalent]
This warning message appears when at
least one array is in an Offline state and
Toggle Pause if Offline is set to ON at
the BIOS Configuration Utility.
If two or more disks in a redundant array
have failed, or if a single or multiple
disks in a non-redundant array have
failed, data has been lost.
In RAID10 array, if a single disk fails in
each mirrored set, the redundant array
goes to a Critical state but data is not
lost. If two disks fail in one of the
mirrored sets, the redundant array goes to
an Offline state and data is lost.
See Section 11.5.1, Troubleshooting
Disks, on page 139.
If, after performing a rescan, the state
remains Offline, the bootable array has
suffered an unrecoverable failure.
Create a new bootable array.
Reinstall the operating system and
drivers.
WARNING: Found
arrays that are Critical
and Offline
[or equivalent]
A bootable array that is in an Offline
state prevents the operating system from
booting.
BIOS NOT INSTALLED -
User Disabled INT13
BIOS Load
[or equivalent]
This warning message appears when
Toggle INT13 Boot Support option has
been set to OFF at the BIOS
Configuration Utility and another boot
device is not selected.
Bootable devices do not function with
the controller when Toggle INT13 Boot
Compartilhe com seus amigos: |