Amd-raidxpert2 User Guide


Table 38. POST Screen Warning Messages



Baixar 1.1 Mb.
Pdf preview
Página197/216
Encontro10.02.2022
Tamanho1.1 Mb.
#21544
1   ...   193   194   195   196   197   198   199   200   ...   216
RAIDXpert2.UserGuide.enu
Table 38. POST Screen Warning Messages 
Warning Message 
Additional Information 
Corrective Action 
WARNING: Found arrays 
that are Critical 
[or equivalent] 
This warning message appears when at 
least one array is in a Critical state and 
Toggle Pause if Critical is set to ON at 
the BIOS Configuration Utility. 
The Critical state of an array depends on 
the RAID level of the array and the 
number of disks that have failed. See 
Section 3.3, Array States, on page 28, for 
information on criticality. 
If an array is Critical (even a bootable 
array), the system can continue through 
the boot process to the operating system.  
See Section 11.5.1, 
Troubleshooting Disks, on 
page 139. 
 